Koster with four 1-phase socket without meter

Koster marina posts with designation GMS E4 or GMS M4 are designed for the modern marina. The post is equipped with four 230V electrical outlet sockets, type IEC216. The outlet sockets are equipped with hardware for a standard padlock and the outlet sockets can be locked with or without the plug inserted. The posts are supplied with 6, 10 or 16A residual current breaker with overload protection. All posts are prepared to be equipped with water tap and hose reel, which are sold as accessories. The residual c Marinpost without measuring 4xIEC outlet 4 RCBO 6A.
E-number
E2449737
Article number
351918
Standard EN61439-3
Short-circuit current [kA] 10kA
Frequency [Hz] 50Hz
Housing material Aluminium
Color Grey
Wire flexible [mm²] 25mm²
Mounting method Floor fastening
Modelltype Koster
Energymeter No
Lock Yes
CEE socket outlet 16A 4pcs 3P 16A 230V
Degree of protection [IP] IPX6
NetProductWeight 11.2
EngineerWidth 253
EngineerHeight 1300
EngineerDepth 250
Name MARINPOST WO MEASURING 4XIEC 6A
E-number E2449737
Article number 351918
Rated current [A] 6A
Number of RCBO [pcs] 4pcs C2P 6A

More variants of Koster with four 1-phase socket without meter

MARINPOST WO MEASURING 4XIEC 16A
E-number
E2449739
Article number
351898
Type designation
GMS E4 16A
Rated current [A]
16A
Number of RCBO [pcs]
4pcs C2P 16A
MARINPOST WO MEASURING 4XIEC 6A
E-number
E2449737
Article number
351918
Type designation
Rated current [A]
6A
Number of RCBO [pcs]
4pcs C2P 6A
MARINPOST WO MEASURING 4XIEC 10A
E-number
E2449738
Article number
351919
Type designation
Rated current [A]
10A
Number of RCBO [pcs]
4pcs C2P 10A

More variants of Koster with four 1-phase socket without meter

E-number Article number Type designation Rated current [A] Number of RCBO [pcs]
MARINPOST WO MEASURING 4XIEC 16A E2449739 351898 GMS E4 16A 16A 4pcs C2P 16A
MARINPOST WO MEASURING 4XIEC 6A E2449737 351918 6A 4pcs C2P 6A
MARINPOST WO MEASURING 4XIEC 10A E2449738 351919 10A 4pcs C2P 10A

Accessories for Koster with four 1-phase socket without meter

ENERGYMETER 1PH PULS
E-number
E0900131
Article number
108043
Type designation
GNM1D
ENERGYMETER 3P PULS
E-number
E0900134
Article number
108046
Type designation
GNM3D
TIME SWITCH 2CHANNEL ASTRO
E-number
E1330553
Article number
108754
Type designation
ASTRO2KT3
MCB C 1P 6A 10kA GS
E-number
E2142705
Article number
2142705
Type designation
MCB C106
RCBO C 2P 6A 10kA 30mA 2M GS
E-number
E2163247
Article number
2163247
Type designation
RCBO C2P 6A 10kA GS
RCBO C 10A 2P 10kA 30mA GS
E-number
E2163248
Article number
2163248
Type designation
RCBO C2P 10A 10kA GS
RCBO C 16A 2P 10kA 30mA 2M GS
E-number
E2163250
Article number
2163250
Type designation
RCBO C2P 16A 10kA GS
RCBO C 16A 4P GS
E-number
E2163272
Article number
2163272
Type designation
RCBO C4P 16A 6kA GS
HOSE HOLDER MARINP
E-number
E2449756
Article number
351937
Type designation
GMS-SH
CABLE POWERCL MARINP
E-number
E2449757
Article number
351955
Type designation
GROUND BASE MARINEPOST
E-number
E2449768
Article number
352030
Type designation
WATERTAP MARIN GMS
E-number
E2449844
Article number
352711
Type designation
GMS-VK-SKY
TERMINAL 5P AL/CU MVC
E-number
E2670477
Article number
353155
Type designation
P5-N
E-number
Article number
353181
Type designation
GMS-L